Title
Corrosion Inhibitor for Multi Metal Cooling Water
Corrosion Inhibitor Additives for Water system ::: Alkaline Corrosion Inhibitor blend for multi-metal protection in closed-loop and chilled cooling water CLOSED circulating system.
This is a Highly effective INHIBITOR for closed loop , line chilled water with unique dual control of corrosion and scale from system.
This closed water treatment chemicals are designed to treat hot and chilled water systems. The product contains a combination of molybdate, borate, and silicate formulated to minimize corrosion and deposition. The product comes in a clear and also a variant pink appearance form.
RXSOL-40-4011-020 is a superior multifunctional, molybdate-based chemical treatment used for the control of corrosion in closed cooling systems and chilled water systems. RXSOL-40-4011-020 is a liquid product containing a combination of ferrous and non-ferrous corrosion inhibitors, a non-carbonate buffer, scale inhibitors, dispersants and a leak detection dye.
Product Remarks
Keep in a tightly closed container in storage closed area . Recommended storage temperature is 500C
Field Note
◦Very effective to Controls corrosion on brass, aluminum, steel, and stainless steel
◦Extends equipment life & Improves overall equipment efficiency
Cooling water treatment specified corrosion inhibitior for multi-metal containng cooling systems to operate at high or low temperatures
For systems containing no aluminium, RXSOL-40-4011-020 should be dosed at 0.5 to 1% (5 L–10 L/ 1000 L) in order to give a reserve of 50 ppm of sodium molybdate. For systems containing aluminium, the dosage of 1–1.5% should be added in order to maintain a minimum reserve of 100 ppm of sodium molybdate. In certain circumstances it may be necessary to adjust the pH separately by the addition of pH CONDITIONER - your Consultant will advise. In systems requiring significant passivation/higher initial dosages may be required to yield the required inhibitor residual.
Normal treated water control limits
pH 7.0 - 9.0 (Without Aluminium)
pH 7.0 - 8.0 (With Aluminium)
For systems containing aluminium it is important to maintain the system water pH in the range 7.0 - 8.0. Occasionally depending on the water characteristics and system treatment history the pH may rise above pH 8.0 which means that the risk of aluminium corrosion is increased - if this happens then high pH can be reduced by adding an appropriate quantity of pH Conditioner.
Corrosion Inhibitor for Multi Metal Cooling Water manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Corrosion Inhibitor for Multi Metal Cooling Water at a competitive price from us. We have ready stock of Corrosion Inhibitor for Multi Metal Cooling Water in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.