Skip to main content
SKU
RXSOL-33-3339-025

Title
RO Antiscalant 2020 High Silica Inhibition

Packing Sizes
Active Matter
Supply Location
Locations

<p>
RO Antiscalant 2020 High Silica Inhibition manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of RO Antiscalant 2020 High Silica Inhibition at a competitive price from us. We have ready stock of RO Antiscalant 2020 High Silica Inhibition in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.</p>

Category
RO Chemicals-33

Short Description

RO Antiscalant 2020 Rx is a high performance non hazardous reverse osmosis (RO) antiscalant and dispersant, scientifically formulated for the treatment and protection of reverse osmosis membranes under high silica feed water conditions.A proprietary blend, RO Antiscalant 2020 Rx has been specifically designed for ro membrane systems with high silica feed-waters.

RO Antiscalant 2020 Rx  is a proven high performance scale inhibitor against calcium carbonate and calcium sulfate scalants and combats silica fouling by a combination of anti-precipitation, anti-agglomeration and dispersancy processes.RO Antiscalant 2020 Rx  is compatible with a wide range of materials and unlike other antiscalants, is not deactivated in the presence of iron.

Product Remarks

Tag Identification

Field Note

Note

<p>
<strong>Product Benefits:</strong><br />
 </p>
<ul>
<li>
Highly efficient antiscalant and dispersant for reverse osmosis membrane systems</li>
<li>
Designed for high silica feedwaters</li>
<li>
Very effective antiscalant</li>
<li>
Prevents low production and poor permeate quality</li>
<li>
Prevents downtime and increased costs</li>
<li>
Combats silica fouling</li>
<li>
Is not deactivated in the presence of iron</li>
<li>
Non Hazardous</li>
</ul>

Technical Specifications

<p>
Product Property :</p>
<table border="0" cellpadding="1" cellspacing="1" style="height: 174px; width: 638px;">
<tbody>
<tr>
<td style="width: 136px;">
Form        </td>
<td style="width: 486px; text-align: justify;">
Liquid</td>
</tr>
<tr>
<td>
Colour</td>
<td style="text-align: justify;">
Amber</td>
</tr>
<tr>
<td>
Odour</td>
<td style="text-align: justify;">
Non</td>
</tr>
<tr>
<td>
Specific Gravity  </td>
<td style="text-align: justify;">
1.10 - 1.15</td>
</tr>
<tr>
<td>
Flash Point</td>
<td style="text-align: justify;">
None</td>
</tr>
<tr>
<td>
Freezing Point</td>
<td style="text-align: justify;">
< – 4oC</td>
</tr>
<tr>
<td>
pH</td>
<td style="text-align: justify;">
4.5 - 7.00</td>
</tr>
<tr>
<td>
Solubility in Water</td>
<td style="text-align: justify;">
Complete Soluble</td>
</tr>
</tbody>
</table>

Application

<p>
can be used in reverse osmosis applications where the reject brine silica levels are as high as 230 ppm at 30oC and pH 7.5. All membrane elements based on Polyamide<br />
chemistries including Thin Film Composite (TFC)<br />
membranes when used as directed Viton<br />
304 Stainless Steel EPDM<br />
Neoprene <br />
Buna-N <br />
Hypalon <br />
Polyurethane <br />
Polyethylene <br />
Polypropylene <br />
Plasite 4300 <br />
Plasite 7122</p>

Dose

<p style="text-align: justify;">
<strong>INSTRUCTIONS FOR USE</strong><br />
 </p>
<p style="text-align: justify;">
<strong>Injecting : </strong>Best results are achieved when RO Antiscalant 2020 High Silica Inhibitionis injected downstream of multimedia filters and upstream of cartridge filters.<br />
<br />
<strong>Dosing : </strong><br />
<br />
A typical RO Antiscalant 2020 High Silica Inhibition dose ranges from 2-5 mg/l. A site-specific dose can be determined using the Avista Advisor software program.<br />
<br />
<strong>Dilution : </strong><br />
<br />
RO Antiscalant 2020 High Silica Inhibition is formulated to be injected neat. However, if dilution is required, use deionized water or RO permeate. If neither of these is available, softened water may be substituted. The dilution for RO Antiscalant 2020 High Silica Inhibition should not result in a solution strength of less than 10%. This guideline will protect the effectiveness of the internal bacteriostat, which inhibits bacterial growth in the product packaging and feed tank.</p>
<ul>
<li>
Use RO permeate for dilution.</li>
<li>
Prepare a fresh antiscalant solution every 2-3 days.</li>
<li>
Inspect the antiscalant day-tank before adding the new solution. If needed, the antiscalant tank should be cleaned prior to filling.</li>
<li>
Dilution rates up to a factor 10 can be applied.</li>
</ul>