Skip to main content
SKU
RXSOL-42-2541-025

Title
Carbohydrazide

Packing Sizes
Active Matter
Supply Location
Locations

<p>Carbohydrazide supplier in Mumbai, Kolkata, Gandhidham, Chennai, Visakhapatnam, Fujairah, Dubai, Abudhabi Sharjah Muscat Oman, Canada. Carbohydrazide&nbsp;<span>plays very important role</span><span>&nbsp;for corrosion protection in boilers water treatment.&nbsp;</span></p>

Category
Boiler Chemicals-42

Short Description

Carbohydrazide in BOILER means no oxygen is entering the boiler  Carbohydrazide will help to decrease oxygen on HP, LP boiler. Carbohydrazid also called Carbodihydrazide, is a high performance oxygen scavenger which can be used in all types of boilers. Carbohydrazide is a white, water-soluble solid that decomposes upon melting point around 153°C.

Product Remarks

Remarks

<p>Carbohydrazide<span>&nbsp;is used as an oxygen scavenger for high pressure boilers in power plants and other industries to reduce corrosion of metal pipes and fittings.</span></p>

Tag Identification

Tag Identification

<p><span><span>Valuable Boiler Water Treatment Chemicals</span> :<br />
<br />
Hydrazine Hydrate (50 ~ 51% as N2H4) plays very important role</span><span>&nbsp;for corrosion protection in boilers.</span><br />
<br />
<span>Activated Hydrazine (34 ~ 35% as N2H4)&nbsp;</span><span>Catalyzed Hydrazine solution for corrosion Protection and related equipment.</span><br />
<br />
<span>Morpholine (C4H9NO).</span><span>&nbsp;</span><span>Technical Grade for Boiler Water Treatment. Purity Not less than 99%.</span><br />
<br />
<br />
<span>Acid Inhibitor :&nbsp;</span><span>For the suppression of Hydrochloric Acid attack on Ferrous alloys, Cuprous alloys and Titanium alloys, effec up to 94°C with efficiency not less than 75% in 5% HCI solution and Acid Inhibitor concentration 2%.</span><br />
<br />
<br />
<span>Ammonia 25% (NH4OH).</span><br />
<span>25% as ammonium Hydroxide used high pressure Boiler water treatment.</span><br />
<span>It is a clear colorless liquid.</span><br />
<span>PH 11-12 @ 20 °C.</span><br />
<span>Density 0.9 g/cm3.</span><br />
<span>Chloride (CL) 0.002 mg/liter maximum.</span><br />
<span>Iron (Fe) 0.002 mg/liter maximum.</span><br />
<br />
<br />
<span>Hardness Stabilizer&nbsp;:</span><br />
<span>Polyacrylate material of low molecular weight.</span><br />
<span>Non-volatile used for scale inhibition in sea water treatment.</span><br />
<span>The product is miscible with water in all proportions. And is clear Liquid.</span><br />
<span>PH valve 5-7.</span><br />
<span>Density @ 20°C Approx. 40%.</span><br />
<span>Chemical Characterization Sodium Polyacrylate, Modified, Aqueous solution.</span><br />
<span>Solidification temperature -20°C.</span><br />
<span>Flash point &gt;100°C.</span><br />
<span>Ignition temperature &gt;200°C.</span></p>

Field Note

Note

<p>As proper level Carbohydrazide protect metal machinery parts from corrosion.</p>

<p><span>Carbohydrazide</span><span>&nbsp;is one of popular an alternative Oxygen Scavenger. It is very important to protect&nbsp;</span><span>boiler components from&nbsp;</span><span>feed boiler water corrosion.&nbsp;</span><br />
&nbsp;</p>

Technical Specifications

<p>Physical properties&nbsp;</p>

<p>molecular formula:OC(N₂H₃)₂</p>

<p>CAS No.:&nbsp;</p>

<p>Molecular weight:90.09</p>

<p>Description:White Solid</p>

<p>odor:Characteristic Smell</p>

<p>Density:1.34 (25/4°C)</p>

<p>&nbsp;&nbsp;</p>

<p>Solubility:Soluble in water, ethanol</p>

<p>vapor density:1.04 (air = 1)</p>

<p>vapor pressure:14.4 mm Hg at 25°C<br />
&nbsp;</p>

Application

<p>Carbohydrazide can be used as oxygen scrubber as direct replacement for Hydrazine in any boiler without the associated safety hazards and handling precautions. The product is based on volatile chemistry and so leaves no dissolved solids and minimal ammonia to the boiler system.&nbsp;</p>

Dose

<p>Carbohydrazide does provide outstanding protection from oxygen corrosion together with excellent feed water and boiler system passivation.Carbohydrazide reacts directly with oxygen. It helps prevent oxygen damage and continues to passivate metal surfaces during wet lay-up. Carbohydrazide can also be used as a curing agent for epoxide-type resins.</p>

Keywords

<p>Recommended dose of&nbsp;<span>Carbohydrazide</span>&nbsp;:</p>

<p>Low Pressure Boiler ( 0 to 40 bar )</p>

<p>0.10 to 0.2 &nbsp;ppm level&nbsp;&nbsp;</p>

<p>Medium Pressure Boiler ( 41 to 60 bar )</p>

<p>&nbsp;0.1 to 0.15 ppm level&nbsp;&nbsp;</p>

<p>High Pressure Boiler ( more then 60 bar)&nbsp;</p>

<p>0.05 to 0.10 ppm level</p>

About

We are professional and reliable provider since we offer customers the most powerful and beautiful themes. Besides, we always catch the latest technology and adapt to follow world’s new trends to deliver the best themes to the market.

Contact info

logo

Tank Cleaner provides marine tank cleaning, degassing, and gas-freeing services for chemical tankers, oil tankers, and gas carriers calling at Indian ports.

Featured Post