Skip to main content
SKU
RXSOL-50-5001-020

Title
One Shot Universal Liquitreat

Packing Sizes
Active Matter
Supply Location
Locations

<p>One Shot Universal Liquitreat manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of One Shot Universal Liquitreat at a competitive price from us. We have ready stock of One Shot Universal Liquitreat in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.</p>

Category
Boiler Chemicals-42

Short Description

It is a well - balanced blend for boiler water treatment products, resulting in a scale and corrosion control by one shot operation. A RXSOL Boiler treatment liquid one-step treatment to control the formation of rust and scale in low pressure and auxillary boilers with working pressure up to 20 bars.

Product Remarks

Tag Identification

Field Note

Note

<p>Basic Boiler System Schematic</p>

<p>Below is a summary of problems associated with the common impurities in water and solutions to each problem.</p>

<p>List Of Problems Caused By Impurities In Water</p>

<p>&nbsp;</p>

<p>Impurity (Chemical Formula)</p>

<p>Problems</p>

<p>Common Chemical Treatment Methods</p>

<p>Alkalinity (HCO3-, CO32- and CaCO3)</p>

<p>Carryover of feedwater into steam, produce CO2 in steam leading to formation of carbonic acid (acid attack)</p>

<p>Neutralizing amines, filming amines, combination of both, and lime-soda.</p>

<p>Hardness (calcium and magnesium salts, CaCO3)</p>

<p>Primary source of scale in heat exchange equipment</p>

<p>Lime softening, phosphate, chelates and polymers</p>

<p>Iron (Fe3+ and Fe2+)</p>

<p>Causes boiler and water line deposits</p>

<p>Phosphate, chelates and polymers</p>

<p>Oxygen (O2)</p>

<p>Corrosion of water lines, boiler, return lines, heat exchanger equipments, etc. (oxygen attack)</p>

<p>Oxygen scavengers, filming amines and deaeration</p>

<p>pH</p>

<p>Corrosion occurs when pH drops below 8.5</p>

<p>pH can be lowered by addition of acids and increased by addition of alkalies</p>

<p>Hydrogen Sulfide (H2S)</p>

<p>Corrosion</p>

<p>Chlorination</p>

<p>Silica (SiO2)</p>

<p>Scale in boilers and cooling water systems</p>

<p>Lime softening</p>

Application

<p>The dosage rate is dependent on bioler operating condition, feed 2-3 ltrs of RXSOL-50-5001-020 solution for per thousand ltr of bioler water then control the system by periodic Alkalinity test procedure. If p-Alkalinity is below 200 ppm increase the ratio of rxsol BWT 5001 solution. If p-Alkalinity is above 400 ppm reduce the concentration of RXSOL-50-5001-020 solution by dilution with water. RXSOL-50-5001-020 is strongly alkaline.RXSOL-50-5001-020&nbsp;&nbsp;is best applied heat or diluted with any convenient strength on a continuous basis using a suitable chemicals pump. The product should be applied to the boiler feed tank or feed line to ensure adequate mixing.<br />
&nbsp;</p>

<p>CHARACTERISTIC :</p>

<ul>
<li>Convenient liquid treatment, which provides the basic alkalinity on which successful water treatment depends.</li>
<li>Provides optimum conditions for hardness control to function.</li>
<li>Neutralizes acid conditions.</li>
<li>Will assist in keeping silica in suspension.</li>
<li>Simple test to determine level of treatment.</li>
<li>Can be used in boilers of all pressures.</li>
<li>Can be used as a neutralizer after acid cleaning operations</li>
<li>Suitable for use with all auxiliary boilers; waste heat units; economizers, package boilers, smoke and water tube boilers.</li>
<li>Dispersant action suspends sludge and sediment particles for efficient blow down.</li>
<li>Oxygen scavenging for optimum protection.</li>
<li>Protects boiler, steam lines, condensate lines and feed water lines from corrosion.</li>
<li>Fast action due to catalyst.</li>
<li>Simple test to determine level of treatment.</li>
</ul>

Dose

<p>Control is by simple&nbsp; boiler water tests or <span>RX CLEANSERS</span>&nbsp; can provide a suitable test&nbsp; kits for this purpose.</p>

<p>Used in low pressure and auxillary boilers</p>

<p><span>:::::::::::::::::::::Alkalinity&nbsp; TEST FOR BOILER &amp; COOLING WATER ::::::::::::::::::::::::</span><br />
<br />
REAGENT &amp; APPARATUS :<br />
Reagent:&nbsp; RXSOL TK 7 , TK 8 , TK 9 , . Apparatus : TEST TUBE , Titrator or DROPPER<br />
<br />
PROCEDURE for p-ALKALINITY &nbsp;test ( STEP WISE ):</p>

<ol>
<li>Measure 10 ml of SAMPLE WATER in graduated TEST TUBE / CYLINDER</li>
<li>Add 1-2 drops of&nbsp; RXSOL TK7 and mix with the stirring rod , If&nbsp; sample turns red / PINK ( which indicates presence of p-Alkalinity ) then follows 3rd step otherwise if sample remains colourless ( Record p-Alkalinity = 0 ) .</li>
<li>Add RXSOL TK9&nbsp; drop by drop ( by counting ) , mixing with the stirring rod until colour just disappears. Each drop is equivalent to 25 ppm of p-Alkalinity , expressed as CaCO3</li>
</ol>

<p>RESULT &nbsp;: Each DROPS is equivalent to&nbsp; 25 PPM of Alkalinity .<br />
<br />
NOTE :&nbsp;&nbsp;&nbsp; p-Alkalinity VALUE&nbsp; =&nbsp; 25 X ( Total Number of DROPS of TK9 , during 3rdstep&nbsp; )</p>

<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>

<p>PROCEDURE for p-ALKALINITY&nbsp; &amp; TOTAL ALKALINITY ( STEP WISE ):</p>

<ol>
<li>Measure 10 ml of SAMPLE WATER in graduated TEST TUBE / CYLINDER</li>
<li>Add 1-2 drops of&nbsp; RXSOL TK7 and mix with the stirring rod , If&nbsp; sample turns red / PINK ( which indicates presence of p-Alkalinity ) then follows 3rd step otherwise if sample remains colourless ( Record p-Alkalinity = 0 ) then proceed to STEP- 4.</li>
<li>Add RXSOL TK9&nbsp; drop by drop ( by counting ) , mixing with the stirring rod until colour just disappears. Each drop is equivalent to 15 ppm of p-Alkalinity , expressed as CaCO3</li>
<li>Add 2-3 drops of RXSOL TK8 and mix with stirring rod , the sample will turn to BLUISH-GREEN .</li>
<li>AddRXSOL TK9 carefully by counting drop by drop and mixing throughly until a light reddish&nbsp; pink&nbsp; colour develop.</li>
</ol>

<p>RESULT&nbsp; : Each DROPS is equivalent to 25 PPM of Alkalinity .</p>

<p>NOTE :&nbsp;&nbsp;&nbsp; p-Alkalinity ppm CaCO3VALUE ( A ) &nbsp;=&nbsp; 25 X ( Total Number of DROPS of TK9 , during 3rdstep&nbsp; )</p>

<p>Total Alkalinity ppm CaCO3VALUE&nbsp; = &nbsp;A +&nbsp; { 25 X ( Total Number of DROPS of TK9 , during 5th&nbsp;step&nbsp; )}</p>

<p>&nbsp;</p>

<p>&nbsp;</p>

<p>&nbsp;</p>

<p>NUMBER OF DROPS OF TK9&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;p-Alkalinity as CaCO3&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>

<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 1 &gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;25<br />
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 2 &gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;50</p>

<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 3 &gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt; &nbsp;75<br />
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 4 &gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&nbsp; 100</p>

<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 5 &gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt; &gt; 125<br />
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 10 &gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt; &gt;&nbsp; 250</p>

<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 20 &gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt; &gt;&nbsp; 500<br />
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 30&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt; &gt;750</p>

<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 40 &gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&gt;&nbsp; 1000<br />
&nbsp;</p>

<p>Optimum Result&nbsp;&nbsp;&nbsp; :&nbsp; &nbsp;p-Alkalinity &nbsp;level &nbsp;is between 100 to &nbsp;150 PPM is suggested.<br />
<br />
&nbsp;if &nbsp;p-Alkalinity level is more then 150 ppm then level should be reduced by increased BLOW DOWN process with immediate effect.&nbsp;&nbsp;&nbsp;</p>

<p>For Below&nbsp; 50 ppm&nbsp; , Dose ½ Ltrs of RXSOL-50-5001-020for 1000 Ltrs of&nbsp; BOILER WATER , to maintain p-Alkalinity level 100 ppm.</p>

<p>Refill pack : REPLACEMENTS &nbsp;</p>

<p>TK7&nbsp;&nbsp; : ECONOMIC PACK ( 100 / 200 / 500 ml ) available</p>

<p>TK8&nbsp;&nbsp; : ECONOMIC PACK ( 100 / 200 / 500 ml ) available</p>

<p>TK9 &nbsp;&nbsp;: ECONOMIC PACK ( 100 / 200 / 500 ml ) available</p>

<p>&nbsp;</p>

<p><a href="http://www.tankcleaner.net/">For Tank cleaning operation pl. click here to know more................&nbsp;</a></p>

<p><span>OTHER VALUABLE PRODUCTS&nbsp;</span></p>

<p><a href="http://rxmarine.com/AlkalinityControl"><span><span><span>Alkalinity Control</span></span></span></a><a href="http://rxmarine.com/AlkalinityTestKit"><span><span><span>Alkalinity Test Kit</span></span></span></a><a href="http://rxmarine.com/BoilerChemicals"><span><span><span>Boiler Chemicals</span></span></span></a></p>

<p><a href="http://rxmarine.com/BoilerCoagulant"><span><span><span>Boiler Coagulant</span></span></span></a><a href="http://rxmarine.com/BoilerWaterSludgeConditoner"><span><span><span>Boil… Water Sludge Conditoner</span></span></span></a><a href="http://rxmarine.com/BoilerWaterTreatmentAuto"><span><span><span>Boiler Water Treatment Auto</span></span></span></a></p>

<p><a href="http://rxmarine.com/CATSulphite"><span><span><span>CAT Sulphite</span></span></span></a><span><span>C</span><span>OMBITREAT</span></span><a href="http://rxmarine.com/CombitreatPwd"><span><span>Combitreat Pwd</span></span></a></p>

<p><a href="http://rxmarine.com/CondensateControl"><span><span>Condensate Control</span></span></a><a href="http://rxmarine.com/CondensolAmine"><span><span>Condensol Amine</span></span></a><a href="http://rxmarine.com/HardnessControl"><span><span>Hardness Control</span></span></a></p>

<p><a href="http://rxmarine.com/node/1275"><span><span>Multiplus BWt</span></span></a><a href="http://rxmarine.com/ONESHOTUNIVERSAL"><span><span>ONE SHOT UNIVERSAL</span></span></a><a href="http://rxmarine.com/OxygenControlCorroisionInhibitor"><span><span>Oxygen Control CorroisionI&nbsp; nhibitor</span></span></a></p>

<p><a href="http://rxmarine.com/OxygenScavangerI"><span><span>Oxygen Scavanger I</span></span></a><a href="http://rxmarine.com/OxygenScavangerPlus"><span><span>Oxygen Scavanger Plus</span></span></a>&nbsp;</p>

About

We are professional and reliable provider since we offer customers the most powerful and beautiful themes. Besides, we always catch the latest technology and adapt to follow world’s new trends to deliver the best themes to the market.

Contact info

logo

Tank Cleaner provides marine tank cleaning, degassing, and gas-freeing services for chemical tankers, oil tankers, and gas carriers calling at Indian ports.

Featured Post