Title
Condensnol Amine Corrosion Control
<p style="text-align: justify;">
Condensnol Amine Corrosion Control manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Condensnol Amine Corrosion Control at a competitive price from us. We have ready stock of Condensnol Amine Corrosion Control in India, UAE Gulf, Barka, Muscat, Sohar, Oman, Kenya Africa. Contact us for bulk as well as small orders.</p>
Short Description
<p style="text-align: justify">
<strong>RXSOL-50-5005-025</strong> Concentrated liquid neutralising agent for corrosion control in condensate and feed water systems, contain blends of low, medium and high volatility amines that provide great protection and neutralization of acidic gases, such as CO<sub>2</sub> throughout a condensate system. <em><span style="font-size:16px;"><span style="color: #000"><span style="background-color: rgb(255,255,255)">Protects boiler surfaces by forming an iron tannate film.</span></span></span></em><br />
A liquid neutralizing amine used to control corrosion and pH in steam and condensate systems.</p>
<p style="text-align: justify">
</p>
<div>
PRODUCT INTRODUCTION</div>
<div>
Pure anisole or methoxybenzene, is an organic compound. CAS NO: 100-66-3</div>
<div>
<div>
HANDLING & STORAGE</div>
<div>
Keep away from heat and sources of ignition.</div>
<div>
Store in a sealed condition at ambient temperature or below. Keep containers in tightly closed condition.</div>
<div>
Use proper PPE during handling.</div>
</div>
<div>
<div>
PRODUCT APPLICATION</div>
<div>
Used as solvent, as an intermediate in making of dyes, pharmaceuticals, fragrances and as an insect pheromones.</div>
</div>
<div>
<div>
PROPERTIES</div>
<div>
Appearance</div>
<div>
Clear Colorless Liquid</div>
<div>
Purity ( by GC ) , %</div>
<div>
99.8 Min</div>
<div>
Specific Gravity @25°C</div>
<div>
0.9995 ± 0.05</div>
<div>
Moisture (by KF) , %</div>
<div>
0.3 Max</div>
</div>
<div>
<div>
PACKAGING</div>
<div>
Packed in drums or in ISO TANKS on request.</div>
</div>
Product Remarks
<p style="text-align: justify;">
<span style="color: #000"><strong><span style="background-color: rgb(255,255,255)">RXSOL-50-5005-025 </span></strong><span style="background-color: rgb(255,255,255)">alkaline and the vapors are irritating to eyes and lungs. Avoid contact with eyes and skin. Do not take internally. Observe safety regulations wear Goggles, PVC gloves and Apron when handling Provide ample ventilation Avoid contact with skin in case of contacts wash with cupious amount of water immediately. If eyes are splashed give immediate and prolonged irrigation with clean running water and obtain medical attention.</span></span></p>
Tag Identification
<p>
<a href="https://rxchemicals.com/Boiler-treatment-chemicals-INDIA-One-Stop-Boile… />
#pHcontrol_amineBASE</a></p>
<p>
<a href="https://rxchemicals.com/Boiler-treatment-chemicals-INDIA-One-Stop-Boile…;
Field Note
<ul>
<li>
<span style="color: #000"><span style="background-color: rgb(255,255,255)">Easy to use liquid treatment.</span></span></li>
<li>
<span style="color: #000"><span style="background-color: rgb(255,255,255)">Neutralizes the acids occurring in the condensate system.</span></span></li>
<li>
<span style="color: #000"><span style="background-color: rgb(255,255,255)">Less maintenance required. Lower operating costs and increased reliability.</span></span></li>
<li>
<span style="color: #000"><span style="background-color: rgb(255,255,255)">Volatilizes and carries over with the steam and so is recycled. Dosage is economical and efficient.</span></span></li>
<li>
<span style="color: #000"><span style="background-color: rgb(255,255,255)">Simple test to determine level of treatment.</span></span></li>
<li>
<span style="color: #000"><span style="background-color: rgb(255,255,255)">Used for protection of condensate and feed water systems in boiler systems of all pressures.</span></span></li>
</ul>
<div>
PRODUCT INTRODUCTION</div>
<div>
Pure anisole or methoxybenzene, is an organic compound. CAS NO: 100-66-3</div>
<div>
<div>
HANDLING & STORAGE</div>
<div>
Keep away from heat and sources of ignition.</div>
<div>
Store in a sealed condition at ambient temperature or below. Keep containers in tightly closed condition.</div>
<div>
Use proper PPE during handling.</div>
</div>
<div>
<div>
PRODUCT APPLICATION</div>
<div>
Used as solvent, as an intermediate in making of dyes, pharmaceuticals, fragrances and as an insect pheromones.</div>
</div>
<div>
<div>
PROPERTIES</div>
<div>
Appearance</div>
<div>
Clear Colorless Liquid</div>
<div>
Purity ( by GC ) , %</div>
<div>
99.8 Min</div>
<div>
Specific Gravity @25°C</div>
<div>
0.9995 ± 0.05</div>
<div>
Moisture (by KF) , %</div>
<div>
0.3 Max</div>
</div>
<p>
</p>
<div>
<div>
PACKAGING</div>
<div>
Packed in drums or in ISO TANKS on request.</div>
</div>
<p>
We carry a complete line of <span style="font-size:16px;">condensate treatment chemicals</span>. Condensate treatment chemicals are used to increase the condensate pH, thus reducing corrosion to the entire boiler steam system. The most common product is a tri-blend amine of cyclohexylamine, morpholine, and diethylaminoethanol (DEAE) neutralizing amines, although we do have standard RXSOL products or we can custom blend to your needs.<br />
RXSOL-50-5005-DCM1 10% DEAE, 10% Cyclo, 10% Morpholine <br />
RXSOL-50-5005-DCM2 20% DEAE, 20% Cyclo, 20% Morpholine <br />
RXSOL-50-5005-C 20% Cyclohexylamine <br />
RXSOL-50-5005-D 20% DEAE <br />
RXSOL-50-5005-M 20% Morpholine <br />
RXSOL-50-5005-C5 50% Cyclohexylamine <br />
RXSOL-50-5005-D 50% DEAE <br />
RXSOL-50-5005-M5 50% Morpholine <br />
</p>
<div>
PRODUCT INTRODUCTION</div>
<div>
Pure anisole or methoxybenzene, is an organic compound. CAS NO: 100-66-3</div>
<div>
<div>
HANDLING & STORAGE</div>
<div>
Keep away from heat and sources of ignition.</div>
<div>
Store in a sealed condition at ambient temperature or below. Keep containers in tightly closed condition.</div>
<div>
Use proper PPE during handling.</div>
</div>
<div>
<div>
PRODUCT APPLICATION</div>
<div>
Used as solvent, as an intermediate in making of dyes, pharmaceuticals, fragrances and as an insect pheromones.</div>
</div>
<div>
<div>
PROPERTIES</div>
<div>
Appearance</div>
<div>
Clear Colorless Liquid</div>
<div>
Purity ( by GC ) , %</div>
<div>
99.8 Min</div>
<div>
Specific Gravity @25°C</div>
<div>
0.9995 ± 0.05</div>
<div>
Moisture (by KF) , %</div>
<div>
0.3 Max</div>
</div>
<div>
<div>
PACKAGING</div>
<div>
Packed in drums or in ISO TANKS on request.</div>
</div>
<p style="text-align: justify">
<strong>RXSOL-50-5005-025</strong> is a blend of volatile liquid / steam distributions ratios that neutralise the acid contaminants in condensate and feed water thus providing protection against acid corrosion in the complete system.The most common cause of acid corrosion in condensate and feed water systems is dissolved carbon dioxide. Condensate control neutralises this acid and maintains the condensate and feed water in an alkaline condition<br />
<span style="font-size:16px;"><em>Used in medium and high-pressure boilers including ultra high-pressure boilers</em></span>.</p>
<p style="text-align: justify">
<span style="color: #000"><u><strong><span style="background-color: rgb(255,255,255)">Fields Of Application:-</span></strong></u><br />
<strong><span style="background-color: rgb(255,255,255)">RXSOL-50-5005-025 is </span></strong><span style="background-color: rgb(255,255,255)">an effective neutralizing type corrosion inhibitor & oxygen scavanger for steam condensation system. And can also be used to protect Boilers /Metals surfaces form corrosion.It removes oxygen efficiently in open feed systems and gives effective corrosion inhibition of boiler/exhaust gas economizer system surfaces . Its Chemical reaction by converting Fe</span><sub><span style="background-color: rgb(255,255,255)">2</span></sub><span style="background-color: rgb(255,255,255)">O</span><sub><span style="background-color: rgb(255,255,255)">3 </span></sub><span style="background-color: rgb(255,255,255)">(rust) to organic iron compound protect further IRON rust reaction .</span></span></p>
<p style="text-align: justify">
<span style="color: #000"><u><strong><span style="background-color: rgb(255,255,255)">Operating Process:-</span></strong></u><br />
<strong><span style="background-color: rgb(255,255,255)">RXSOL-CC72 </span></strong><span style="background-color: rgb(255,255,255)">neutralizes the acid components of feed water.The proportion of </span><strong><span style="background-color: rgb(255,255,255)">RXSOL-50-5005-025</span></strong><span style="background-color: rgb(255,255,255)"> depends upon the </span><strong><span style="background-color: rgb(255,255,255)">Carbon dioxide</span></strong><span style="background-color: rgb(255,255,255)"> content of the condensate. Basically </span><strong><span style="background-color: rgb(255,255,255)">RXSOL-50-5005-025 </span></strong><span style="background-color: rgb(255,255,255)">neutralizes the acid contents & maintains the condensate and feed water in the alkaline condition. It also protects copper based metals.</span></span></p>
<div>
<div>
<u><em><strong>PRODUCT APPLICATION</strong></em></u></div>
<div>
Used as solvent, as an intermediate in making of dyes, pharmaceuticals, fragrances and as an insect pheromones.</div>
</div>
<p style="text-align: justify">
<span style="color: #000"><strong><span style="background-color: rgb(240,255,240)">RXSOL-50-5005-025</span></strong><span style="background-color: rgb(240,255,240)"> condensate is tested for PH to determine the dosage level. The PH limits are 8.3 - 9.0 . For an average system e. g. 10-M</span><sup><span style="background-color: rgb(240,255,240)">3</span></sup><span style="background-color: rgb(240,255,240)">, the dosage is approximately 0.65 ltr / day .</span></span><br />
<br />
<span style="color: #000"><span style="background-color: rgb(255,255,255)">The necessary amount of </span><strong><span style="background-color: rgb(255,255,255)">RXSOL-50-5005-025</span></strong><span style="background-color: rgb(255,255,255)"> is required or injected as frequently as to maintain the pH of the condensate at the main condensate pump outlet between 8.6-9.5 . The amines pass over with the steam and have the dual function of elevating the pH of the steam/condensate and putting a protective micro film on the system pipe work. Acidic condensate is the result of carbonic acid (H</span><sub><span style="background-color: rgb(255,255,255)">2</span></sub><span style="background-color: rgb(255,255,255)">CO</span><sub><span style="background-color: rgb(255,255,255)">3</span></sub><span style="background-color: rgb(255,255,255)">) being formed as CO</span><sub><span style="background-color: rgb(255,255,255)">2</span></sub><span style="background-color: rgb(255,255,255)"> is released in the steam.Condensate prevents corrosion by carbonic acid on live systems. Its filming properties also reduce corrosion on shut down lines, when moisture and oxygen are present.</span></span></p>
<p style="text-align: justify">
Not Compatible:<span style="white-space:pre"> </span>Avoid copper, brass and aluminium.</p>
<p style="text-align: justify">
</p>
<p data-end="422" data-start="0">
<strong data-end="24" data-start="0">Sampling and Testing</strong><br data-end="27" data-start="24" />
A representative condensate sample should be collected daily for analysis. The sample must always be taken from the same sampling point, cooled, and tested immediately. Testing should be carried out strictly in accordance with the test kit instructions, and all results must be recorded.</p>
<p data-end="535" data-start="424">
<strong data-end="488" data-start="424">Condensate Control - Dosing Parameters (all pressure ranges)</strong><br data-end="491" data-start="488" />
The normal operating pH range is 8.5 to 9.2.</p>
<p data-end="900" data-start="537">
<strong data-end="552" data-start="537">Measured pH</strong><br data-end="555" data-start="552" />
<strong>If the pH is below 8.5</strong>, increase the dosage by 25% and re-test after 24 hours, or sooner if required.<br data-end="659" data-start="656" />
<strong>If the pH is within the range of 8.5 to 9.2</strong>, the system is under control and no dosage adjustment is required; continue routine monitoring.<br data-end="801" data-start="798" />
<strong>If the pH is above 9.2</strong>, reduce the dosage by 25% and re-test after 24 hours, or sooner if required.</p>
<p data-end="1059" data-start="902">
These values are recommended based on operational experience and are not intended to override boiler manufacturer guidelines or company operating procedures.</p>
<p data-end="1232" data-is-last-node="" data-is-only-node="" data-start="1061">
Regular testing is essential to ensure that treatment levels remain correct. Refer to the dosage chart to maintain the condensate pH within the target range of 8.5 to 9.2.</p>
<p>
<span style="font-size:20px;">Boiler Treatment Chemical <strong>ONE STOP SOLUTION LINK</strong></span> ::: <br />
<br />
<a href="https://rxchemicals.com/Boiler-treatment-chemicals-INDIA-One-Stop-Boile…;