Skip to main content
SKU
RXSOL-22-2216-025

Title
HBI CARGO Hold Wash Concentrate RX 25 Ltrs

Packing Sizes
Active Matter
Supply Location
Locations

<p style="text-align: justify;">
HBI Cargo Residue Cleaner Chemical is helpful to  clean HBI cargo stain by chemicals cleaning and reactive principle. We are  HBI CARGO Residue cleaner supplier in Paradip, Haldia, Hazira, Mundra, Kandla, Ennore, Kochin, Visakhapatnam, Sohar, Muscat, Fujairah, Dubai, Sharjah, Mumbai, Manglore and Goa, Ruwi Barka, Abudhabi, Ajman, Sudan, Yemen, Canada</p>

Category
Deck cabin galley Maintenance-25

Short Description

<p style="text-align: justify">
Accumulation of dust from this cargo on deck or in proximity to cargo spaces shall be removed as quickly as possible. Consideration shall be given to carefully cleaning exposed radio communications equipment to which dust might adhere, such as radar, radio, aerials, vhf installations, AIS and GPS. <em><span style="font-size:16px;">Hosing with sea water should be avoided.</span></em><br />
HBI CARGO Hold Wash Concentrate RX  is a versatile all-purpose QUALITY marine cleaning solution. It can be used as a powerful stand-alone cleaner for HBI CARGO .  it can be used as a powerful\ stand alone cleaner  for HBI CARGO dust and deposition  .<br />
 </p>

Product Remarks

Remarks

<p style="text-align: justify;">
<span style="font-size:18px;">HBI at Elevated Temperatures</span><br />
The Master of the ship must notify the port authorities if hydrogen gas is detected in the ship holds or if abnormal temperatures are measured in the HBI cargo holds. The Harbor Master and qualified personnel are responsible for executing the action plan when a ship or barge arrives with HBI at the following temperature levels:<br />
<br />
<span style="font-size:16px;"><strong>A. Greater Than 65° Celsius but Less Than or Equal to 80° Celsius<br />
Proceed with the following actions:</strong></span><br />
1 > Before unloading the vessel, measure the HBI temperature in each hold and record the measurements in the temperature log book.<br />
2 >  Unload the holds in the assigned zone and immediately transfer the HBI to the storage yard zone as described in PART II, Section 5.4 of this guide.<br />
<br />
<span style="font-size:16px;"><strong>B. Temperature Greater Than 80° Celsius and Less Than or Equal to 150°<br />
Celsius</strong></span><br />
Proceed with the following actions:<br />
1 > Before unloading the vessel, measure the HBI temperature in each hold and record the measurements in the temperature log book. This should be done every two hours while the contingency is in effect.<br />
2 >  Unload the holds with HBI at temperature less than 65º Celsius first, then those containing HBI between 65º and 100º Celsius. Continue unloading HBI with temperatures between 100º and 150º Celsius in the<br />
first transfer station, using the movement sense of the belt as a<br />
reference.<br />
3 >  Transfer the HBI from the unloading zone clean and free of debris and flammable material, such as coal, coke and wood to the storage yard indicated by the client as follows:<br />
Transfer the HBI during a maximum of three-minute intervals, and dose (i.e., mix the hotter with the cooler material to have an average temperature lower than the hottest one – no water to be used) the HBI that is at temperatures between 100° and 150° Celsius with cooler material for a maximum of two minutes. Stop the vibrating feeders for about five minutes, but keep the conveyor belts in motion. Repeat these steps until finished with HBI removal. While transferring the HBI, inspect the belt transfer system for any sign of overheating. In case of belt overheating, stop the HBI dosing and transfer but keep the transfer belts in motion until they cool. Take special care to avoid pouring water into hoppers and other equipment. Use a front-end loader to spread the HBI to a level of approximate 30 centimeter height to stop the reoxidation,  Verify that the belts are cooled down and resume HBI transfer per<br />
the previous instructions.<br />
<br />
<br />
<span style="font-size:16px;"><strong>C . Greater than 150° Celsius</strong></span><br />
Proceed with the following actions:<br />
1 > Before unloading the holds, measure the HBI temperature in each hold and record the measurements in the temperature log book. This should be done every two hours while the contingency is in effect.<br />
2 > Position the HBI with temperatures greater than 150° Celsius at the end of the reception area and spray with pressurized water. In this case, there is no option but to momentarily cool down the HBI.<br />
3 >  When the temperature is reduced to between 80º and 150° Celsius proceed with the steps described in 6.3.2.2. Caution: Do not spray water on hot HBI that is steaming (i.e., emitting water vapor). </p>
<p>
<span style="font-size:16px;"><strong><span style="font-size:18px;">Procedure If Hydrogen Concentration Is Over</span> 1% (25% LEL)</strong></span><br />
1 > Inform the shipper immediately and seek expert advice.<br />
2 > Keep the natural surface ventilation open at all times<br />
3 > Monitor LEL in the holds continuously until level drops to less than 25 %.<br />
4 > Avoid any possible ignition source on the vicinity.<br />
5 > Care shall be taken as to prevent any spark generation.<br />
6 > Monitor the hydrogen concentration in the holds and keep the surface ventilation (either natural or mechanical) until values fall below 1%.<br />
7 > When hydrogen levels are within safe values, proceed as normal.<br />
8 > On the contrary, additional ventilation should be applied to the space if available and re-testing should be conducted after a suitable interval.<br />
9 > Contact the P & I Club and Shipper and follow the instructions of the appointed expert or surveyor.<br />
10 > At sea, do not open the troubled hold without explicit instructions from the shipper or appointed expert or surveyor.<br />
11 > Ensure there are no possible sources of ignition near the cargo spaces, adjacent spaces or open decks.</p>

Tag Identification

Tag Identification

<br />

Field Note

Note

<p>
<strong>Features & Benefit:-</strong></p>
<ul>
<li>
Heavy duty HBI CARGO cleaning power</li>
<li>
Can be diluted to suit cleaning needs</li>
<li>
Environmentally friendly</li>
<li>
Safe to use onto the occupied areas /covered areas</li>
<li>
Reduces the turnaround times</li>
<li>
Cam be easily applied by ship’s crew</li>
</ul>
<p>
<span _fck_bookmark="1" style="display: none"> </span></p>

Technical Specifications

<br />

Application

<p>
FEATURES & BENEFITS :-------------------<br />
$ Heavy duty HBI CARGO  remover action<br />
$ Can be diluted to suit cleaning needs<br />
$ Environmentally friendly<br />
$ Safe to use in occupied / covered areas<br />
$ Reduces turnaround times<br />
$ Can be easily applied by ship's crew<br />
$ using an RXSOL Application Set</p>

Industrial Area

<p style="text-align: justify;">
 </p>
<div id="cke_pastebin">
<p style="text-align: justify;">
Other Valuable Hold Cleaners :::</p>
<p style="text-align: justify;">
Cement Remover RX Hold ::: Highly concentrated and powerful penetrating agents materials which is effectively react with cement to loosen the bonding strength . Best results can obtain on dry surface of cement. RXSOL'S R & D has developed this molecular cement dissolver. Part No.- RXSOL-22-2202-025, Part No.- RXSOL-22-2202-020,  Part No.- RXSOL-22-2202-050</p>
<div>
<p style="text-align: justify;">
Part No.- RXSOL-22-2202-035, Part No.- RXSOL-22-2202-210</p>
<div style="text-align: justify;">
 </div>
<div>
<div style="text-align: justify;">
 </div>
<div style="text-align: justify;">
Slip Barrier Coat RXSOL HOLD BLOCK  ::: Polymer EMULSION BASED non reactive coating materials which makes thin film barrier on surface after dry. Due to formation of RXSOL THIN barrier film on surface, the cleaning operation after unloading becomes quicker and easier with optimum results. Part No.- RXSOL-22-2210-210, Part No.- RXSOL-22-2210-025, Part No.- RXSOL-22-2210-050</div>
<div style="text-align: justify;">
 </div>
<div style="text-align: justify;">
BARRIER HOLD COAT ::: Highly effective ecofriendly Product blending of natural ingredients which is provide thin temprory film on Hold Surface to protect corrosion. This is making barrier between corrosive cargo like Sulphur, Salt, Petcoak, Cement etc and Hold surface. Part No.- RXSOL-22-2211-210</div>
<div style="text-align: justify;">
 </div>
<div style="text-align: justify;">
COAL REMOVER rx hold  ::: A powerful penetrating mixed chemical products to remove heavy coal deposits. Additionally, it may also be used to remove mineral deposits and eliminate bad odors in tanks and other closed systems. Part No.- RXSOL-22-2215-210, Part No.- RXSOL-22-2201-025, Part No.- RXSOL-22-2201-050</div>
<div style="text-align: justify;">
 </div>
<div style="text-align: justify;">
 </div>
<div style="text-align: justify;">
Hold Wash Concentrate RX ::: RXSOL hold wash is a versatile all purpose marine cleaning solution it can be used as a powerful stand alone cleaner for Petroleum oily stains and residues, vegetable and animal fats, as well as dirt, proteins, soils, coal, ore, coke or in combination. Part No.- RXSOL-22-2204-210, Part No.- RXSOL-22-2204-025, Part No.- RXSOL-22-2204-050</div>
<div style="text-align: justify;">
 </div>
<div style="text-align: justify;">
 </div>
<div style="text-align: justify;">
Rock Phosphate Cleaner rx hold  ::: A powerful penetrating mixed chemical products to remove heavy Rock Phospate deposits. Additionally, it may also be used to remove mineral deposits and eliminate bad odors in tanks and other closed systems. Part No.- RXSOL-22-2201-210</div>
<div style="text-align: justify;">
 </div>
<div style="text-align: justify;">
PCS Hold Clean ::: RXSOL PCS is an innovative, concentrated liquid product specifically engineered to attack, penetrate and remove Coal Carbon, pet coke, lime deposition accumulations from cargo and storage tanks, Also Developed for cargo hold cleaning to remove stains.  Part No.- RXSOL-22-2208-210</div>
<div style="text-align: justify;">
 </div>
<div style="text-align: justify;">
HBI CARGO Hold Wash Concentrate RX::: RX HBI CARGO Hold Wash Concentrate RX is a versatile all-purpose QUALITY marine cleaning solution. It can be used as a powerful stand-alone cleaner for HBI CARGO . it can be used as a powerful\ stand alone cleaner for HBI CARGO dust and deposition. Part No.- RXSOL-22-2216-210, Part No.- RXSOL-22-2216-025</div>
<div style="text-align: justify;">
 </div>

Dose

<br />

Useful Area

<br />

Keywords

<br />

About

We are professional and reliable provider since we offer customers the most powerful and beautiful themes. Besides, we always catch the latest technology and adapt to follow world’s new trends to deliver the best themes to the market.

Contact info

logo

Tank Cleaner provides marine tank cleaning, degassing, and gas-freeing services for chemical tankers, oil tankers, and gas carriers calling at Indian ports.

Featured Post