Skip to main content
Corrosion Inhibitor Closed Cooling systems
SKU
RXSOL-40-4011-210

Title
Corrosion Inhibitor Closed Cooling systems

Corrosion Inhibitor Additives for Water system
This is a Highly effective INHIBITOR for closed loop , line chilled water with unique dual control of corrosion and scale from system.

This closed water treatment chemicals are  designed to treat hot and chilled water systems. The product contains a combination of nitrite, borate, and silicate formulated to minimize corrosion and deposition. The product comes in a clear and pink appearance form.
 

RXSOL-40-4011-0210 is a superior multifunctional, nitrite-based chemical treatment used for the control of corrosion in closed cooling systems and chilled water systems. RXSOL-40-4011-0210 is a liquid product containing a combination of ferrous and non-ferrous corrosion inhibitors, a non-carbonate buffer, scale inhibitors, dispersants and a leak detection dye.

Category
Evaporator Treat-51

Product Remarks

Remarks

<p>
<span style="font-size:14px;">Keep in a tightly closed container in storage closed area .</span> Recommended storage temperature is 50<sup>0</sup>C<br />
 </p>

Field Note

Note

<p>
◦Very effective to Controls corrosion on brass, aluminum, steel, and stainless steel<br />
◦Extends equipment life & Improves overall equipment efficiency</p>

Technical Specifications

<br />

Application

<br />

Industrial Area

<p style="text-align: justify;">
<span style="font-size: 14px; text-align: justify;">RXSOL-40-4011 is a liquid, Nitrite/Borate based compound with unique formulation with organic Corrosion Inhibitors, Anti-Scalant for use in closed cooling water systems , for preventing corrosion and scale F</span><span style="font-size: 14px; text-align: justify;">ormation in Internal combustion engines, compressor cooling system, DG -set at high or low temperature. It is also acts as a corrosion inhibitor Protects all the metals including cast iron, mild steel, copper etc</span></p>

Dose

<p style="text-align: justify;">
Compatible with Feeders, piping and valves should be made of steel, polyethylene, or PVC. This Treatment can be controlled by a nitrite test.<br />
<br />
The recommended dosage of RXSOL-40-4011-0210 is 15.6-23.4 l/m3 of system capacity or 60.6-87 RXSOL-40-4011-0210 of system capacity in all systems. Clean up the system if the system becomes contaminated with iron. Maintain 600-750 ppm nitrite as NO2. RXSOL-40-4011-0210  is intended for industrial use only. It should not be fed to potable water systems</p>

Locations

<p style="text-align: justify;">
Corrosion Inhibitor Closed Cooling systems manufacturer and supplier in Mumbai, Kandla, Surat Gujarat, Chennai, Visakhapatnam, Kolkata, Haldia, Fujairah, Sharjah, Ajman, Abudhabi, Dubai, UAE GUlf, Ruwi Barka Muscat Oman, Nairobi Kenya, Sudan Yemen Canada</p>

About

We are professional and reliable provider since we offer customers the most powerful and beautiful themes. Besides, we always catch the latest technology and adapt to follow world’s new trends to deliver the best themes to the market.

Contact info

logo

Tank Cleaner provides marine tank cleaning, degassing, and gas-freeing services for chemical tankers, oil tankers, and gas carriers calling at Indian ports.

Featured Post