Title
ROCCOR NB Corrosion
COOLING WATER CORROSION & SCALE INHIBITOR
Corrosion Inhibitor for Water Systems having unique formulation with highly concentrated liquid cooling treatment compound, ferrous & Non ferrous corrosion inhibitors, antiscalants, dispersant and buffer solution of non carbonate. Usefull for use in high or low temperature closed cooling water systems for the prevention of corrosion and scale formation in internal combustion engines, compressors, chiller system and DG sets. Protects all metals including cast iron, mild steels and copper. Recommended ppm levels are easily controlled by standered RXSOL test kit Nitrite / Chloride.
The stable protective microfilm prevents corrosion caused by electrolytic action and the alkaline nature of this product prevents acid attack.
The stability of the added polymers are very useful for water treatment processes. Such polymers with low molecular weights cannot only inhibit calcium, magnesium, and silica scale in cooling towers and boilers, but also help corrosion control by dispersing iron oxide.
Product Remarks
<p style="text-align: justify;">
<span style="font-family: arial, sans-serif; font-size: 12.8px;">Before testing of Nitrite level, Here is some point and guideline, what you need to do. : <strong>1</strong> take the following readings; pH, TDS </span><span style="font-family: arial, sans-serif; font-size: 12.8px;">(uS), and nitrite level.and record. <strong>2</strong> add the Chemical your are using. </span><span style="font-family: arial, sans-serif; font-size: 12.8px;"><strong>3</strong>. wait for a period of time for the sysem to circulate. <minimum 3 -4 </span><span style="font-family: arial, sans-serif; font-size: 12.8px;">hours> <strong>4</strong>. Re check the readings. and record. 5 track these readings</span><br style="font-family: arial, sans-serif; font-size: 12.8px;" />
<span style="font-family: arial, sans-serif; font-size: 12.8px;">for a period of time.</span><br style="font-family: arial, sans-serif; font-size: 12.8px;" />
<br style="font-family: arial, sans-serif; font-size: 12.8px;" />
<span style="font-family: arial, sans-serif; font-size: 12.8px;">If the TDS and Nitrite drop you have a leak/ unknown makeup. if the </span><span style="font-family: arial, sans-serif; font-size: 12.8px;">TDS stays stable and the nitrite drops you have a biological problem. </span><span style="font-family: arial, sans-serif; font-size: 12.8px;">Bacteria that convert nitrite to nitrate.</span><br style="font-family: arial, sans-serif; font-size: 12.8px;" />
<br style="font-family: arial, sans-serif; font-size: 12.8px;" />
<span style="font-family: arial, sans-serif; font-size: 12.8px;">Solution ::: Use DI water in place of general water, And also use. </span><span style="font-family: arial, sans-serif; font-size: 12.8px;">Algaecide to control Bacterial growth inside water system ... </span><a data-saferedirecturl="https://www.google.com/url?hl=en&q=http://rxmarine.com/Biocide-Algaecid…; href="http://rxmarine.com/Biocide-Algaecide" rel="noreferrer" style="color: rgb(17, 85, 204); font-family: arial, sans-serif; font-size: 12.8px;" target="_blank">http://rxmarine.com/Biocide-<wbr>Algaecide</wbr></a></p>
Tag Identification
<div id="cke_pastebin" style="text-align: justify;">
CWT ROCCORRX NB Corrosion Scale Inhibitor Liquid msds and technical bulletine available here.<br />
CWT ROCCORRX NB Corrosion Scale Inhibitor Liquid is one of classified corrosion inihibitor for cooling water system. Ferrous and Non ferrous metal parts of cooling water system gets corrosion and changes into pitting formation which results in the form of leakage and many more. But presence of balance level of nitrite and borax which is main compenent of CWT ROCCORRX NB Corrosion Scale Inhibitor Liquid, effectively control corrosion on metal surface, This is the reason why uses of ROCCORRX NB liquid is most common in COOLING WATER SYSTEM on the other hand we can say that CWT ROCCORRX NB Corrosion Scale Inhibitor Liquid is the ideal corrosion inhibitor for closed heating or cooling systems, such as diesel engines, compressors, process cooling systems, etc.</div>
Field Note
<p style="text-align: justify">
Initial dosage for an untreated system is 9 litres of RXSOL-40-4001-025 / 1000 litres of untreated distilled water. This will bring the treatment up to the minimum level of 1000 ppm nitrite. For best result and prolonged engine life add RXSOL-40-4001-025 every 500 -6500 km. or 250 to 300 hours of running time or every 2 month interval. Specially designed for use in water systems of internal combustion equipment. pH should be maintained between 8.3 and 10 by the treatment.</p>
<p style="text-align: justify">
<span style="font-size:14px;"><em>RXSOL-40-4001-025 will react with sludge and in most cases, facilitate sludge gradual removal. On badly fouled systems with oil or scale, a prior degreasing by using DEGREASER HEAVY DUTY or descaling by using DEGREASER HEAVY DUTY, SCALE REMOVER LIQUID or SCALE REMOVER POWDER is highly recommended.</em></span></p>
<p>
• Excellent corrosion inhibitor for cooling water</p>
<p>
• Minimises metal oxide deposits</p>
<p>
• Protects ferrous and non-ferrous metals</p>
<p>
• Compatible with glycol-based antifreeze</p>
<p>
• Reduces cleaning & maintenance costs</p>
<p>
• Cost effective, easy to apply and use</p>
<p style="text-align: justify;">
RX MARINE INTERNATIONAL are continiously working in water treatement sector, And developed many unique product to avoid corrosion and scale depositon in cooling water system. Here I wants to keep our experiment results with you.Corrosion inhibitor for closed cooling systems containing molybdate/phosphonate ( <a href="http://rxmarine.com/Corrosion-inhibitor-closed-cooling-systems-molybdat…; ). <span style="font-family: arial, sans-serif; font-size: small; text-align: justify;">Sodium molybdate has the advantage in that the dosing of lower ppm's of molybdate allow for lower conductivity of the circulating water. Sodium molybdate at levels of 50-100 ppm offer the same levels of corrosion inhibition that sodium nitrite at levels of 800+ ppm. By utilizing lower concentrations of sodium molybdate, conductivity is kept at a minimum and thus galvanic corrosion potentials are decreased.</span></p>
<p style="text-align: justify">
Prolongs the life of equipment by keeping it scale and corrosion free. Since RXSOL-40-4001-025 is alkaline, it will<span style="font-size: 16px"><em> suppress acid corrosion</em></span>, which would otherwise result in sever pittings. It improves cooling efficiency by maintaining clean heat transfer surfaces , from Radiators, DG - sets, Closed Cooling and chiller System.<br />
<br />
FIELDS ::: --- Suitable for use in closed water cooling systems, ice melting systems and transformer cooling systems. The product may be used in all kinds of diesel & petrol engines, compressor or heating cooling water circuits.<br />
<br />
<br />
<span style="font-size:16px;"><em>( Used as a corrosion inhibitor for all ferrous and non-ferrous metals found in water systems )</em></span></p>
<p>
What is closed cooling system ?<br />
<br />
The full closed cooling system is designed to circulate cooling water through the block and exhaust manifold. water is circulated through water pump to heat exchanger tank and be pumped through many small tubes where it will exchange heat from the water of the circulating system. Then water exits the heat exchanger to go directly into the risers and then exit the boat. The exhaust manifold and riser will be blocked off, so no water will transfer between them. As for the circulating water in the closed cooling system, cool water will enter the engine through the circulating pump and circulate through the engine. The water will heat up in the engine and the warm water will exit at the water outlet on top of the manifold and head to the manifolds. After circulating through the manifolds, the hot water will head to the heat exchanger to exchange the heat it's carrying with the raw water. After the exchange the cool circulating water exits the heat exchanger and returns to circulating pump to begin another loop. <br />
</p>
<div id="cke_pastebin">
<strong>How to Protect internal combustion engines, compressors, chiller system and DG sets from Corrosion?</strong></div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
ROCCOR NB Corrosion Inhibitor is a unique formulation with highly concentrated liquid cooling treatment compound, ferrous & Non ferrous corrosion inhibitors, antiscalants, dispersant and buffer solution of non carbonate.</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
ROCCOR NB is specialized such a way which can be use in high or low temperature closed cooling water systems for the prevention of corrosion and scale formation in internal combustion engines, compressors, chiller system and DG sets. Also Usefull to Protects all metals including cast iron, mild steels and copper. Recommended ppm levels are easily controlled by standered RXSOL test kit Nitrite / Chloride.</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
The stable protective microfilm prevents corrosion caused by electrolytic action and the alkaline nature of this product prevents acid attack.</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin" style="text-align: justify;">
The stability of the added polymers are very useful for water treatment processes. Such polymers with low molecular weights cannot only inhibit calcium, magnesium, and silica scale in cooling towers and boilers, but also help corrosion control by dispersing iron oxide. </div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin" style="text-align: justify;">
FIELDS ::: --- Suitable for use in closed water cooling systems, ice melting systems and transformer cooling systems. The product may be used in all kinds of diesel & petrol engines, compressor or heating cooling water circuits.</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
<strong>Where Roccor NB can be used?</strong></div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin" style="text-align: justify;">
Prolongs the life of equipment by keeping it scale and corrosion free. Since RXSOL-40-4001-025 is alkaline, it will suppress acid corrosion, which would otherwise result in sever pittings. It improves cooling efficiency by maintaining clean heat transfer surfaces , from Radiators, DG - sets, Closed Cooling and chiller System.</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
FIELDS ::: --- Suitable for use in closed water cooling systems, ice melting systems and transformer cooling systems. The product may be used in all kinds of diesel & petrol engines, compressor or heating cooling water circuits.</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
( Used as a corrosion inhibitor for all ferrous and non-ferrous metals found in water systems )</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
<strong>DOSES and Using procedure of ROCCOR NB?</strong></div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
GENERAL RECOMMENDATION : ( The dosage chart may be used as a guide to adjust treatment to obtain the optimum level.)</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
Nitrite (as PPM NO2) 0 100-200 300-600 700-900 1100-1300 </div>
<div id="cke_pastebin">
RXSOL-40-4001-025 / 1000L 8.0 7.3 7-8 5-7 1.5-3.5</div>
<div id="cke_pastebin">
NOTE ::: -- If nitrite level becomes 1440-2400 then doses should be ZERO.</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin" style="text-align: justify;">
The initial dosage for an untreated system is 8 liters of product per 1000 liters of water. Such a dose will bring nitrite levels over 1200 ppm. Maximum nitrite level is considered to be 2400 ppm. Frequent tests should be carried out in order to maintain pH values within the limit (8.3-10.0), while levels of chloride should be maximum 50 ppm.</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin" style="text-align: justify;">
Initial dosage for an untreated system is 9 litres of RXSOL-40-4001-025 / 1000 litres of untreated distilled water. This will bring the treatment up to the minimum level of 1000 ppm nitrite. For best result and prolonged engine life add RXSOL-40-4001-025 every 500 -6500 km. or 250 to 300 hours of running time or every 2 month interval. Specially designed for use in water systems of internal combustion equipment. pH should be maintained between 8.3 and 10 by the treatment.</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin" style="text-align: justify;">
RXSOL-40-4001-025 will react with sludge and in most cases, facilitate sludge gradual removal. On badly fouled systems with oil or scale, a prior degreasing by using DEGREASER HEAVY DUTY or descaling by using DEGREASER HEAVY DUTY, SCALE REMOVER LIQUID or SCALE REMOVER POWDER is highly recommended.</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
• Excellent corrosion inhibitor for cooling water</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
• Minimises metal oxide deposits</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
• Protects ferrous and non-ferrous metals</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
• Compatible with glycol-based antifreeze</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
• Reduces cleaning & maintenance costs</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin" style="text-align: justify;">
• Cost effective, easy to apply and use<br />
<br />
ROCCOR NB Corrosion Scale Inhibitor Liquid specialized marine chemical product for Cooling Water treatment. ROCCOR NB Corrosion Scale Inhibitor Liquid supplier in Mumbai, Kandla Mundra, TURBHA MIDC NAVI Mumbai, Hazira SURAT, Visakhapatnam, Gangavaram, Chennai, Ennore, Kolkata, Haldia, Paradip, Kakinada, Fujairah, Ajman, Abudhabi, Sharjah, Dubai, UAE GULF, Ruwi Gala Barka, Muscat Oman, Canada, Nairobi Kenya Sudan, Yemen</div>
<p>
Refer to technical datasheet.</p>
<p style="text-align: justify">
<strong>GENERAL RECOMMENDATION</strong> : ( The dosage chart may be used as a guide to adjust treatment to obtain the optimum level.)</p>
<table border="0" cellpadding="1" cellspacing="1" style="width: 517px; height: 113px">
<tbody>
<tr>
<td style="width: 25%">
Nitrite (as PPM NO2)</td>
<td style="width: 15%">
<span style="background-color: #00ff00">0 </span></td>
<td style="width: 15%">
<span style="background-color: #ffff00">100-200</span></td>
<td style="width: 15%">
<span style="background-color: #ffff00">300-600</span></td>
<td style="width: 15%">
<span style="background-color: #ffff00">700-900</span></td>
<td style="width: 15%">
<span style="background-color: #f00">1100-1300 </span></td>
</tr>
<tr>
<td>
RXSOL-40-4001-025 / 1000L</td>
<td>
<span style="background-color: #00ff00">8.0 </span></td>
<td>
<span style="background-color: #ffff00">7.3</span></td>
<td>
<span style="background-color: #ffff00">7-8 </span></td>
<td>
<span style="background-color: #ffff00">5-7 </span></td>
<td>
<span style="background-color: #f00">1.5-3.5 </span></td>
</tr>
</tbody>
</table>
<p style="text-align: justify;">
NOTE ::: -- <em><span style="font-size: 14px"> If nitrite level becomes 1440-2400 then doses should be ZERO</span></em>.<br />
<br />
The initial dosage for an untreated system is 8 liters of product per 1000 liters of water. Such a dose will bring nitrite levels over 1200 ppm. Maximum nitrite level is considered to be 2400 ppm. Frequent tests should be carried out in order to maintain pH values within the limit (8.3-10.0), while levels of chloride should be maximum 50 ppm.<br />
</p>
<p style="text-align: justify;">
Also refer this link <a href="http://rxmarine.com/engine-water-treatment-corrosion-inhibitor">http://… />
<br />
CWT RoccorRX NB Corrosion Scale Inhibitor Liquid manufacturer and supplier in Mumbai, turbhe Pawana Navi Mumbai, Panvel, Taloja, Gandhidham, Kandla, Mundra, Jamnagar, Hazira, Surat, Manglore, Chennai Ennore, Visakhapatnam, Gangavaram, Kolkata, Haldia, Paradip Odisha, Fujairah, Dubai, Ajman, Abudhbai, Muscat Oman Barka Sohar, Canada<br />
<br />
ROCCOR Nitrite Borax with proprietory mixture is most popular Corrosion Inhibitor for <span style="font-size:16px;">cooling water jacketed system</span>.</p>
<p style="text-align: justify;">
<span style="font-size:14px;">How to Protect internal combustion engines, compressors, chiller system and DG sets from Corrosion?</span><br />
<br />
ROCCOR NB Corrosion Inhibitor is a unique formulation with highly concentrated liquid cooling treatment compound, ferrous & Non ferrous corrosion inhibitors, antiscalants, dispersant and buffer solution of non carbonate.<br />
<br />
ROCCOR NB is specialized such a way which can be use in high or low temperature closed cooling water systems for the prevention of corrosion and <em><span style="font-size: 16px;">scale formation</span></em> in internal combustion engines, compressors, chiller system and DG sets. Also Usefull to Protects all metals including cast iron, mild steels and copper. Recommended ppm levels are easily controlled by standered RXSOL test kit Nitrite / Chloride.</p>
<p style="text-align: justify;">
<br />
The stable protective microfilm prevents corrosion caused by electrolytic action and the alkaline nature of this product prevents acid attack.</p>
<p style="text-align: justify;">
The stability of the added polymers are very useful for water treatment processes. Such polymers with low molecular weights cannot only inhibit calcium, magnesium, and silica scale in cooling towers and boilers, but also help corrosion control by dispersing iron oxide. </p>
<div>
<div id="cke_pastebin">
During Circulation of water mainly controlling of 2 factors required : -</div>
</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin" style="text-align: justify;">
SCALE CONTROL in closed water cooling systems - Diesel and gas engines releasing high temperature due to that water present in jacket cooling system increases its tendency to deposit scale. To avoid scale formation water softener like Zeolite gradual buildup of scale in cylinders and cylinder heads. Where condensate is available, it is preferred for closed system cooling water makeup. Where condensate is not available, zeolite softening should be applied to the makeup water.</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin" style="text-align: justify;">
CORROSION CONTROL An increase in water temperature causes an increase in corrosion. At high temperature solubility of oxygen in water decreases due to that Corrosion rates increasing inside the system. This occurs because the lower solubility of oxygen with increasing temperatures in a freely vented system decreases the corrosion rate faster than the rise in temperature increases it. However, in many closed systems, the dissolved oxygen entering the system in the makeup water cannot be freely vented, resulting in the release of oxygen at points of high heat transfer, which may cause severe corrosion. Untreated systems can suffer serious corrosion damage from oxygen pitting, galvanic action, and crevice attack. Closed cooling systems that are shut down periodically are subjected to water temperatures that may vary from ambient to 180°F (82°C) or higher. During shutdown, oxygen can enter the water until its saturation limit is reached. When the system is returned to high-temperature operation, oxygen solubility drops and the released oxygen attacks metal surfaces. </div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin" style="text-align: justify;">
The three most reliable corrosion inhibitors for closed cooling water systems are chromate, molybdate, and nitrite materials. Generally, the chromate or molybdate types have proven to be superior treatments.</div>
<div id="cke_pastebin">
ROCCOR NB Corrosion Inhibitor</div>
<div id="cke_pastebin" style="text-align: justify;">
The closed cooling system uses the water flowing through a heat exchanger to remove heat from the engines. If Continuous flow of cooling water contains ROCCORRX Nb corrosion inhibitor and antifreeze mixture resulting good protect towards metal surface. <br />
<br />
CWT ROCCORRXRX NB Corrosion Scale Inhibitor Liquid is classified marine chemical corrosion inhibitor for engine cooling water systems. ROCCORRX NB Liq effectively protects ferrous and non-ferrous metals of engine cooling system. RXSOL CWT ROCCORRXRX NB Corrosion Scale Inhibitor Liquid is used in diesel engines, compressors, process cooling systems as ROCCOR nb liquid is the suitable and most popular corrosion inhibitor for closed heating or cooling systems of machinery and engine system.<br />
<br />
CWT ROCCORRXRX NB Corrosion Scale Inhibitor Liquid equivalent product is CWT Diessel NB Guard, Liqui dewt, ROCCORRX NB liquid</div>
