Title
AMERZAMINE
<p style="text-align: justify;">
<span style="font-size:16px;">100 percent water soluble and 100 percent Volatile corrosion inhibitor for Low Medium High Pressure Boiler Water System.</span><br />
<span style="font-size: 14px; text-align: justify;">Corrosion Inhibitor for Boiler Neutralizer Concentrated liquid neutralising agent for corrosion control in condensate and feed water systems, contain blends of low, medium and high volatility amines that provide great protection and neutralization of acidic gases, such as CO</span><sub style="text-align: justify;">2</sub><span style="font-size: 14px; text-align: justify;"> throughout a condensate system. </span><span style="font-size: 14px; text-align: justify; color: rgb(0, 0, 0);">Protects boiler surfaces by forming an iron tannate film.</span><br style="font-size: 14px; text-align: justify;" />
<span style="font-size: 14px; text-align: justify;">A liquid neutralizing amine used to control corrosion and pH in steam and condensate systems.</span></p>
Product Remarks
<p>
<strong>Basic Boiler System Schematic</strong></p>
<p>
Below is a summary of problems associated with the common impurities in water and solutions to each problem.</p>
<p>
<strong>List Of Problems Caused By Impurities In Water</strong></p>
<table border="0" cellpadding="0" cellspacing="0">
<tbody>
<tr>
<td style="width: 219px; height: 33px;">
<p align="center">
<strong>Impurity (Chemical Formula)</strong></p>
</td>
<td style="width: 219px; height: 33px;">
<p align="center">
<strong>Problems</strong></p>
</td>
<td style="width: 219px; height: 33px;">
<p align="center">
<strong>Common Chemical Treatment Methods</strong></p>
</td>
</tr>
<tr>
<td style="width: 219px; height: 45px;">
<p>
Alkalinity (HCO<sub>3</sub>-, CO<sub>3</sub><sup>2- </sup>and CaCO<sub>3</sub>)</p>
</td>
<td style="width: 219px; height: 45px;">
<p style="text-align: justify;">
Carryover of feedwater into steam, produce CO<sub>2 </sub>in steam leading to formation of carbonic acid (acid attack)</p>
</td>
<td style="width: 219px; height: 45px;">
<p style="text-align: justify;">
Neutralizing amines, filming amines, combination of both, and lime-soda.</p>
</td>
</tr>
<tr>
<td style="width: 219px; height: 31px;">
<p>
Hardness (calcium and magnesium salts, CaCO<sub>3</sub>)</p>
</td>
<td style="width: 219px; height: 31px;">
<p style="text-align: justify;">
Primary source of scale in heat exchange equipment</p>
</td>
<td style="width: 219px; height: 31px;">
<p style="text-align: justify;">
Lime softening, phosphate, chelates and polymers</p>
</td>
</tr>
<tr>
<td style="width: 219px; height: 17px;">
<p>
Iron (Fe<sup>3+ </sup>and Fe<sup>2+</sup>)</p>
</td>
<td style="width: 219px; height: 17px;">
<p style="text-align: justify;">
Causes boiler and water line deposits</p>
</td>
<td style="width: 219px; height: 17px;">
<p style="text-align: justify;">
Phosphate, chelates and polymers</p>
</td>
</tr>
<tr>
<td style="width: 219px; height: 30px;">
<p>
Oxygen (O<sub>2</sub>)</p>
</td>
<td style="width: 219px; height: 30px;">
<p style="text-align: justify;">
Corrosion of water lines, boiler, return lines, heat exchanger equipments, etc. (oxygen attack)</p>
</td>
<td style="width: 219px; height: 30px;">
<p style="text-align: justify;">
Oxygen scavengers, filming amines and deaeration</p>
</td>
</tr>
<tr>
<td style="width: 219px; height: 30px;">
<p>
pH</p>
</td>
<td style="width: 219px; height: 30px;">
<p style="text-align: justify;">
Corrosion occurs when pH drops below 8.5</p>
</td>
<td style="width: 219px; height: 30px;">
<p style="text-align: justify;">
pH can be lowered by addition of acids and increased by addition of alkalies</p>
</td>
</tr>
<tr>
<td style="width: 219px; height: 17px;">
<p>
Hydrogen Sulfide (H<sub>2</sub>S)</p>
</td>
<td style="width: 219px; height: 17px;">
<p>
Corrosion</p>
</td>
<td style="width: 219px; height: 17px;">
<p>
Chlorination</p>
</td>
</tr>
<tr>
<td style="width: 219px; height: 17px;">
<p>
Silica (SiO<sub>2</sub>)</p>
</td>
<td style="width: 219px; height: 17px;">
<p style="text-align: justify;">
Scale in boilers and cooling water systems</p>
</td>
<td style="width: 219px; height: 17px;">
<p>
Lime softening</p>
</td>
</tr>
</tbody>
</table>
Field Note
<div>
<p align="justify">
<span style="font-size:16px;">Why </span><span style="font-size: 16px;">AMERZAMINE corrosion inhibitor is important for Boiler System?</span><br />
<span style="font-size:16px;">AMERZAMINE corrosion inhibitor form protective oxide films and passivates metal surfaces.</span></p>
</div>
<ul>
<li>
<span style="color: rgb(0, 0, 0);">Easy to use liquid treatment.</span></li>
<li>
<span style="color: rgb(0, 0, 0);">Neutralizes the acids occurring in the condensate system.</span></li>
<li>
<span style="color: rgb(0, 0, 0);">Less maintenance required. Lower operating costs and increased reliability.</span></li>
</ul>
<p style="text-align: justify;">
<span style="font-size:16px;">Hydrazine Based oxygen scavenger and Corrosion inhibitor controls ferrous and non-ferrous corrosion in feedwater, boilers, steam, and condensate lines.</span></p>
<p style="text-align: justify;">
<br />
Corrosion Inhibitor for Boiler Neutralizer is a blend of volatile liquid / steam distributions ratios that neutralise the acid contaminants in condensate and feed water thus providing protection against acid corrosion in the complete system.The most common cause of acid corrosion in condensate and feed water systems is dissolved carbon dioxide. Condensate control neutralises this acid and maintains the condensate and feed water in an alkaline condition<br />
<span style="font-size: 16px;"><em>Used in medium and high-pressure boilers including ultra high-pressure boilers</em></span>.</p>
<p style="text-align: justify;">
<span style="color: rgb(0, 0, 0);"><u><strong>Fields Of Application:-</strong></u></span><br />
<strong>Corrosion Inhibitor for Boiler Neutralizer</strong><span style="color: rgb(0, 0, 0);"><strong> is </strong>an effective neutralizing type corrosion inhibitor & oxygen scavanger for steam condensation system. And can also be used to protect Boilers /Metals surfaces form corrosion.It removes oxygen efficiently in open feed systems and gives effective corrosion inhibition of boiler/exhaust gas economizer system surfaces . Its Chemical reaction by converting Fe<sub>2</sub>O<sub>3 </sub>(rust) to organic iron compound protect further IRON rust reaction .</span></p>
<p style="text-align: justify;">
<span style="color: rgb(0, 0, 0);"><u><strong>Operating Process:-</strong></u><br />
<strong>RXSOL-CC72 </strong>neutralizes the acid components of feed water.The proportion of </span><strong>Corrosion Inhibitor for Boiler Neutralize</strong>r<span style="color: rgb(0, 0, 0);"> depends upon the <strong>Carbon dioxide</strong> content of the condensate. Basically<strong> </strong></span><strong>Corrosion Inhibitor for Boiler Neutralizer</strong><span style="color: rgb(0, 0, 0);"><strong> </strong>neutralizes the acid contents & maintains the condensate and feed water in the alkaline condition. It also protects copper based metals.</span></p>
<div>
<div>
<u><em><strong>PRODUCT APPLICATION</strong></em></u></div>
<div style="text-align: justify;">
Used as solvent, as an intermediate in making of dyes, pharmaceuticals, fragrances and as an insect pheromones.</div>
</div>
<p>
AMERZAMINE manufacturer and supplier in India UAE Oman. AMERZAMINE Boiler Condensate Corrosion Control chemical manufacturer supplier in India UAE Oman.</p>
<p style="text-align: justify;">
<span style="font-size: 16px;">AMERZAMINE </span><span style="text-align: justify; background-color: rgb(175, 238, 238);">Corrosion Inhibitor for Boiler Neutralizer</span><span style="text-align: justify; color: rgb(0, 0, 0);"><span style="background-color: rgb(240, 255, 240);"> condensate is tested for PH to determine the dosage level. The PH limits are 8.3 - 9.0 . For an average system e. g. 10-M</span><sup><span style="background-color: rgb(240, 255, 240);">3</span></sup><span style="background-color: rgb(240, 255, 240);">, the dosage is approximately 0.15 ltr / day .</span></span><br style="text-align: justify;" />
<br style="text-align: justify;" />
<span style="text-align: justify; color: rgb(0, 0, 0);">The necessary amount of </span><strong style="text-align: justify;">Corrosion Inhibitor for Boiler Neutralizer</strong><span style="text-align: justify; color: rgb(0, 0, 0);"> is required or injected as frequently as to maintain the pH of the condensate at the main condensate pump outlet between 8.6-9.5 . The amines pass over with the steam and have the dual function of elevating the pH of the steam/condensate and putting a protective micro film on the system pipe work. Acidic condensate is the result of carbonic acid (H<sub>2</sub>CO<sub>3</sub>) being formed as CO<sub>2</sub> is released in the steam.Condensate prevents corrosion by carbonic acid on live systems. Its filming properties also reduce corrosion on shut down lines, when moisture and oxygen are present.</span></p>